Better Counts for Better Science
Cell counting is a fundamental quality control procedure in research. It’s simple. It’s straightforward. But it’s also error-prone, time-consuming, and highly subjective. Logos' automated cell counters are equipped with high-quality optics and sophisticated software to bring you cell concentration and viability data with incredible speed, accuracy, and reliability.
It’s as simple as pressing COUNT!
The Standard For Accurate Cell Counting
Cell counting is a critical and routine part of many cell culture laboratory workflows. The practice usually involves directly counting individual cells in a small volume in order to get an estimate of how many cells are in a larger volume. This can be useful for culture maintenance, setting up assays, assessing the health or viability of cells in a culture, and clinical or diagnostic applications.
Take your cell counting to the next level
With a growing emphasis on both inter- and intra-lab reproducibility in research, the seemingly simple act of getting accurate cell counts is now more important than ever. Logos' image-based automated cell counters act as your eyes, a microscope, image-analysis software, and a computer to produce consistently accurate and reliable cell counts.
The LUNA series are equipped with high-quality optics and sophisticated
software that make cell counting as simple as inserting your sample and pressing ‘count’.
Cell concentration and viability data, images, and histograms are at your fingertips in as little as 7 seconds.
Contact us to hear more about automated cell counting and cell counters.
We can also offer you a demo!
Anja Fjorback:
af@bionordika.dk
+45 2381 1912
Compare Cell Counters
Main features
Most affordable cell counter.
Versatile cell counter that serves a wide variety of applications. An excellent choice for higher throughput and/or regulatory needs.
Versatile and affordable fluorescence cell counter with manual focus.
Fluorescence cell counter specialized for SVF derived- cells.
Affordable yeast cell counter.
Image-based bacterial cell counter.
Cell Types
Stable cell lines
Cell lines
Primary cells
Whole blood
PBMCs
Splenocyte
Thymocyte
Yeast cells
Cell lines
Primary cells
Blood cells
PBMCs
Splenocyte
Thymocyte
Yeast cells
GFP expressing cells
Stem cells
SVF-derived cells
• Nucleated
• Non-nucleated
Yeast cells
Bacterial cells
Detection Method
Brightfield
Dual fluorescence
Brightfield
Dual fluorescence
Brightfield
Dual fluorescence
Dual fluorescence
Fluorescence
Compatible Dyes
Trypan blue
Erythrosin B
Trypan blue
Erythrosin B
Acridine orange
Propidium iodide
Fluorescein diacetate
Trypan blue
Erythrosin B
Acridine orange
Propidium iodide
Fluorescein diacetate
Acridine orange
Propidium iodide
Acridine orange
Propidium iodide
Fluorescein diacetate
QUANTOM Total Cell
Staining Kit
QUANTOM Viable Cell
Staining Kit
Recommended Slide Options
LUNA™ Cell Counting SlidesLUNA™ Reusable Slide
PhotonSlides
LUNA™ 1-Channel Slide
LUNA™ 3-Channel Slide
LUNA™ 8-Channel Slide
PhotonSlide™
LUNA™ Reusable Slide
PhotonSlide™
LUNA™ Reusable Slide
PhotonSlide™
LUNA™ Reusable Slide
QUANTOM™ M50
Cell Counting Slides
Focusing options
Autofocus
Manual focus
Autofocus
Manual focus
Manual focus
Manual focus
Autofocus
Manual focus
Autofocus
Manual focus
Counting Speed
< 10 s (manual focus)
< 15 s (autofocus)
< 10 s (brightfield, without autofocus, 12 images)
< 20 s (brightfield, with autofocus, 12 images)
< 30 s (fluorescence, without autofocus, 12 images)
< 40 s (fluorescence, with autofocus, autofocus, 12 images)
< 10 s (brightfield)
< 30 s (fluorescence)
< 30 s
< 10 s (manual focus)
< 15 s (autofocus)
< 30 s (autofocus, 10 images)
Adjustable Protocol Parameters
Cell size
Declustering
Dilution factor
Live cell sensitivity
Noise reduction
Roundness
Search size / Cell size
Cell detection sensitivity
Live cell sensitivity
Noise reduction
Fluorescence exposure
Fluorescence threshold
Dilution factor
Cell size
Dilution factor
Fluorescence threshold
Live cell sensitivity
Noise reductionRoundness
Cell size
Dilution factor
Fluorescence threshold
Noise reduction
Roundness
Fluorescent object size
Dilution factor
Fluorescence exposure
Light intensity
Fluorescent object size
Dilution factor
Roundness
Declustering
Multi-field imaging
Additional Features
Cell size gating
Cluster map
Dilution calculator
Review previous count
results
Auto exposure
Cell size gating
Cluster map
Dilution calculator
Review previous count
results
Bioprocess
Quality control
Reanalysis
Auto exposure
GFP expression analysis
Cell size gating
Cluster map
Dilution calculator
Review previous count
results
Auto exposure
Cell size gating
Cluster map
Dilution calculator
Review previous count
results
Fluorescent object size
gating
Dilution calculator
Review previous count
results
Fluorescent object size
gating
Dilution calculator
Review previous count
results
Reanalysis
IQOQ Protocol
Yes
Yes
Yes
Yes
-
Yes
21 CFR Part 11 ready
-
Yes(With CountWire™ software)
-
-
-
-
Saving Options
Cell count and viability data (CSV)
Raw image (TIF)
Analyzed image (annotated TIF)
Full report (PDF)
Cell count and viability data (CSV)
Raw image (TIF)
Analyzed image (annotated TIF)
Full report (PDF)
Bioprocess (Onboard, CSV, PNG graph images)
Quality Control (Onboard, CSV, PNG graph images)
Cell count and viability data (CSV)
Raw image (TIF)
Analyzed image (annotated TIF)
Full report (PDF)
Cell count and viability data (CSV)
Raw image (TIF)
Analyzed image (annotated TIF)
Full report (PDF)
Cell count and viability data (CSV)
Raw image (TIF)
Analyzed image (annotated TIF)
Full report (PDF)
Cell count data (CSV)
Raw image (TIF)
Analyzed image (annotated TIF)
Full report (PDF)
Data Transfer
USB memory stick
USB memory stick, WiFi, Ethernet
USB memory stick
USB memory stick
USB memory stick
USB memory stick, WiFi
Technical Specifications
5” TFT LCD screen
800 X 480 pixels
Built-in computer
Built-in printer (optional)
7” TFT LCD screen
1024 X 600 pixels
Built-in computer
External printer (optional)
7” TFT LCD screen
800 X 480 pixels
Built-in computer
External printer (optional)
7” TFT LCD screen
800 X 480 pixels
Built-in computer
External printer (optional)
5” TFT LCD screen
800 X 480 pixels
Built-in computer
Built-in printer (optional)
10” TFT LCD screen
1280 x 800 pixels
Built-in computer
External printer (optional)
Onboard Storage
-
250GB / 1TB
-
-
-
128GB
Weight
1.6 kg (3.5 lb)
4.5 kg (9.9 lb)
1.8 kg (4 lb)
1.8 kg (4 lb)
1.8 kg (3.9 lb)
10.8 kg (23.9 lb)
Dimensions
16 x 18 x 28 cm
(6.3 x 7.0 x 11.0 in)
24.5 x 28 x 24 cm
(9.6 x 11.0 x 9.4 in)
22 x 21 x 9 cm
(8.6 x 8.3 x 3.5 in)
22 x 21 x 9 cm
(8.6 x 8.3 x 3.5 in)
16 x 18 x 28 cm
(6.3 x 7.0 x 11.0 in
43.3 × 31.0 × 22.5 cm
(17.0 x 12.2 x 8.8 in)
For more information, please contact:
Anja Fjorback
+45 23811912
af@bionordika.dk